Soccer Stadium Lighting 1500W LED Floodlight 160LM/W FIFA Grade Uniformity IP66 Housing
Product Details:
| Place of Origin: | Guangdong, China |
| Brand Name: | Fins board, BOCAQ |
| Certification: | CE, RoHS, FCC, PSE, UL, ISO 9001 |
| Model Number: | SSL-S1500 |
Payment & Shipping Terms:
| Minimum Order Quantity: | 50 Pieces |
|---|---|
| Price: | USD 120-680 / Piece |
| Packaging Details: | Foam cradle in five-layer export carton, palletised for FCL or LCL shipment |
| Delivery Time: | 15-25 working days after deposit |
| Payment Terms: | T/T, L/C, Western Union |
| Supply Ability: | 5000 Pieces per Month |
|
Detail Information |
|||
| Model: | SSL-S1500 | Rated Power: | 1500W (1000W And 1800W Versions Available) |
|---|---|---|---|
| Luminous Efficacy: | 160LM/W At 5000K | Luminous Flux: | 240000LM Typical |
| Input Voltage: | AC 200-480V, 50/60Hz | Optics: | Dual Chamber 25° Plus 60°, Asymmetric |
| Uniformity: | Above 0.7 On 21 X 15 Point Grid | Color Temperature: | 4000K / 5000K / 5700K |
| IP Rating: | IP66, IK09 | Colour Consistency: | 3 Step MacAdam Ellipse |
| Control: | DALI-2 / 0-10V, 10-100 Percent | Color Rendering Index: | Ra > 80 (Ra > 90 Optional) |
| Lifespan: | 100000 Hours L90B10 | ||
| Highlight: | 1500W LED stadium floodlight,160LM/W FIFA grade stadium light,IP66 LED stadium lighting housing |
||
Product Description
Soccer stadiums that must satisfy inspection bodies need more than brightness; they need uniformity ratios documented to the millimetre of the grid. This 1500W luminaire is supplied with photometric data measured on a 21 by 15 point grid, so designers can prove uniformity above 0.7 and gradient values inside FIFA recommendations before poles are ordered. The dual chamber optic mixes narrow and wide distributions in one housing, which lets an eight pole scheme serve a competition pitch and a training pitch from the same fixture type, and the IP66 housing keeps performance stable through a full season outdoors.
- FIFA Grade Uniformity: Measured photometry supports uniformity above 0.7 and controlled gradient values, giving inspectors documented evidence rather than a calculated guess.
- Dual Chamber Optic: Narrow and wide distributions share one housing, so a competition pitch and an adjacent training area can be served from a single fixture type.
- 160LM/W Output: Efficient light engine keeps connected load low enough for existing switchgear on retrofit projects where pole wiring cannot be upgraded.
- Glare Controlled Design: Recessed cells and a 30 degree cut off keep glare low for players, officials and spectators in the first rows of the stand.
- IP66 and IK09 Build: Impact resistant lens and sealed gasket withstand ball strikes, hail and pressure washing between matches.
- Colour Consistency: Three step MacAdam binning keeps colour uniform across all fixtures, so the pitch does not show patches after a phased installation.
- Fast Mast Service: Plug in driver modules with coded connectors allow electronics replacement at height without removing the luminaire from the cross arm.
| Parameter | Specification |
|---|---|
| Model | SSL-S1500 |
| Rated Power | 1500W (1000W and 1800W versions available) |
| Luminous Efficacy | 160LM/W at 5000K |
| Luminous Flux | 240000LM typical |
| Input Voltage | AC 200-480V, 50/60Hz |
| Optics | Dual chamber 25° plus 60°, asymmetric |
| Uniformity | Above 0.7 on 21 x 15 point grid |
| Color Temperature | 4000K / 5000K / 5700K |
| IP Rating | IP66, IK09 |
| Colour Consistency | 3 step MacAdam ellipse |
| Control | DALI-2 / 0-10V, 10-100 percent |
| Color Rendering Index | Ra > 80 (Ra > 90 optional) |
| Lifespan | 100000 hours L90B10 |
| Warranty | 5 years |
Soccer clubs, academy campuses and municipal stadiums specify this fixture when inspection compliance is written into the contract. It suits new build schemes where the lighting design is approved before construction, and it also fits upgrades where old metal halide floodlights are replaced on the existing masts without touching the pole layout. Because the dual chamber optic can be aimed for the main pitch and the warm-up area together, facilities that run academy sessions before evening fixtures avoid a second lighting circuit, and groundsmen benefit from fewer fixtures to clean, inspect and re-aim each season.
- FIFA and national federation inspected competition pitches
- Academy campuses with adjacent training and warm-up areas
- Metal halide to LED retrofits on existing masts
- Municipal stadiums with staged fixture replacement budgets
Units ship individually cartoned with a reinforced foam cradle and a separate accessory box for brackets, aiming bolts and cable glands. Twelve cartons load on a standard pallet for stable container stacking. Production includes a 72 hour burn-in, isolation and earth bond testing, plus photometric sampling and a uniformity report per order. Compliance documentation covers CE, RoHS, FCC, PSE, UL recognised components and ISO 9001 manufacturing. Spare drivers, gaskets and lenses remain available throughout the warranty, and a commissioning guide with aiming tables is supplied for the installing contractor.